Backup power for agriculture

Backup power for agriculture is about ensuring that critical functions on the farm continue when the power grid fails. This could be ventilation in barns, milking and feeding systems, cooling, pumps, and other operations where a stoppage can quickly result in significant losses. With the right solution, you can both reduce the risk of power outages and achieve more flexible energy operations in your day-to-day work. Here, we review how backup power for agriculture is typically structured, which technologies are used, and what you need to keep track of in terms of requirements, finances, and operations.

What does backup power mean for agriculture, and why is it a critical part of operations?

Backup power for agriculture is emergency power or buffer capacity that keeps critical processes running during power outages. For livestock production, the need is often acute because animals can be harmed without ventilation, heat, water, and feed. Power outages can also affect automated equipment, where even short outages can trigger operational stoppages, false alarms, and consequential errors that take time to normalize again.

A practical way to clarify the need is to distinguish between these two levels:

  • Necessary functions: Those that must run continuously to avoid critical operational consequences.
  • Buffer capacity: Capacity to keep the farm running for a period of time while the supply is restored or an alternative energy source takes over.

Once you have separated "must run" from "can wait," it becomes much easier to design a solution that both works in practice and is economically viable.

Start right: Identify critical consumers for backup power for agriculture

Before choosing technology, you should prioritize consumers and map out the consequences of failure. Critical consumers vary from farm to farm, but typical examples are ventilation systems, automatic milking systems, feeding systems, cooling systems (e.g., for milk), water pumps, and in some cases heating systems. The decisive factor is not only what is critical, but also how the equipment reacts when the power goes out and comes back on.

A needs analysis should include the following to ensure that an otherwise good system does not fall short on the details:

  • Identification: Which installations must not fail?
  • Power and starting current: Many appliances use 2–5 times more power when starting up than during continuous operation.
  • Duration: How long should the backup cover – hours or longer?
  • Continuity: Should there be "no interruption" (UPS function), or is a short pause acceptable?

As a practical exercise, you can also consider whether backup power should cover the entire facility or whether you can establish a "critical panel"/critical circuits. This reduces power requirements and makes it more realistic to ensure stable operation during outages.

Backup power for agriculture with battery (BESS): Fast response and flexible operation

Battery energy storage (BESS) has become a dominant choice for backup power for agriculture. A BESS stores energy in batteries (typically lithium-ion, often LiFePO₄) and supplies power during grid outages or when electricity prices are high. The system usually consists of battery modules, an inverter (DC to AC), a battery management system (BMS), and energy management. In practice, it is precisely the interaction between the inverter, BMS, and control that determines how stable and predictable the system behaves when it really matters.

A key advantage is response time: BESS can switch to backup in milliseconds, which is relevant for sensitive and automated equipment. This means that in many cases, you can avoid having to restart and recalibrate controls, sensors, and automation systems after a brief outage. In addition, a battery can be used for daily optimization:

  • Peak shaving: The battery can reduce peak loads and thus power-related costs.
  • Solar integration: Surplus production can be stored instead of being sold at a low price.
  • Energy trading: The system can purchase electricity when it is inexpensive and utilize it when it is costly.

To get the most out of daily use, you should clarify how energy management prioritizes between backup readiness and optimization. In practice, this means ensuring that there is always sufficient capacity "in reserve" so that the battery does not run out when there is a power outage.

Capacities typically range from around 100 kWh to several MWh. As a rule of thumb, 50–100 kWh may be relevant for smaller operations, while larger livestock production may require 200–300 kWh. In the event of a blackout, the system can be configured to automatically switch from supplying the entire facility to supplying only critical circuits. This is often where projects benefit from well-thought-out scenarios: What should continue unchanged, what can be throttled down, and what can be shut down in a controlled manner?

Generators as backup power for agriculture: Strengths, operation, and limitations

Generators are a classic solution for emergency power. They can supply power continuously as long as there is fuel, and are therefore suitable for prolonged outages. In agriculture, tractor-driven generators (PTO) are often recommended because the farm typically already has the tractor and because it reduces the need to maintain a separate engine. A tractor-driven generator can be purchased for around DKK 20,000.

For a generator to actually function as a backup, it must be part of an operating routine. It is particularly important to clarify who does what in the event of a failure: who starts and monitors, how the load is connected, and how you ensure that critical functions are prioritized first.

The disadvantages are important to consider in the decision:

  • Maintenance: Generators require ongoing servicing and should be tested regularly; in practice, at least monthly operational testing is recommended.
  • Noise and emissions: Operation generates CO₂ and NOx, among other things.
  • Efficiency: Typically around 35–40%.
  • Fuel supply: Prolonged crises can make fuel difficult to obtain.

If you choose a generator, it is a good idea to make testing a regular part of your operations so that any faults are detected under controlled conditions and not in the middle of a critical situation.

Hybrid backup power for agriculture: Battery and generator in the same setup

A hybrid solution combines a battery and a generator. The battery takes over for the first few milliseconds in the event of a power failure and can optimize everyday operations, while the generator can take over during longer outages or charge the battery. In some cases, hybrid systems can significantly reduce generator operating time (by up to 96%), which can mean less maintenance and lower fuel consumption.

In practice, a hybrid solution can also make it easier to size the generator more precisely according to demand. The battery can handle short peaks and starting currents, while the generator provides a more stable, longer-lasting supply. This can result in smoother operation, especially when there are many motors and varying loads.

Requirements for backup power for agriculture: Documentation, safety, and grid connection

Emergency power and battery systems must be handled as electrical installations with a focus on electrical safety, fire protection, and proper grounding. For grid-connected solutions, the system must ensure that power does not flow into the grid during fault conditions. This is typically done via an automatic circuit breaker or anti-islanding function on the inverter. For you as a plant owner, this means that functionality in the event of a grid failure is not only a question of capacity, but also of proper protection and disconnection.

The requirements also depend on how much the plant runs:

  • Less than five minutes per month: May be subject to a more limited set of requirements.
  • More than five minutes per month: Classified as a standard production facility and must meet all relevant technical requirements, including the use of tested and compatible components.

This makes it important to be clear about how the system is expected to be used in daily operations. A solution that is primarily intended as emergency power may have other requirements if, in practice, it also runs regularly for optimization purposes.

In addition, there is typically a focus on:

  • Fire safety and location: Insurance companies often have limits on indoor capacity (typically 50–100 kWh), and larger systems are often placed outdoors or in approved containers.
  • Registration: The system must be registered with the local electricity network operator.
  • Documentation prior to commissioning: Electrical diagrams, fire plan, and other documentation must be in place prior to permanent commissioning.

When documentation and registration are handled early in the process, you reduce the risk of delays, extra costs, and uncertainty in relation to insurance and operation.

Economics of backup power for agriculture: Price level and realistic payback

Costs depend on size, power requirements, location, and installation and fire safety requirements. For BESS, all-in projects are estimated at around DKK 900–1,000/kWh. An example of a 200 kWh system is estimated at approximately DKK 270,000–370,000, including battery, inverter/BMS, installation/fire safety, grid connection, and approvals.

To assess the economics of your case, you should start with your actual load profile: when do peaks occur, which processes can be moved, and how much of the consumption is actually critical in the event of an outage. This provides a better basis for decision-making than looking at capacity alone.

There are documented cases where the combination of solar cells and batteries provides significant annual savings, e.g., an example with 38 kWp solar cells and a 215 kWh battery, where costs are significantly reduced. At the same time, the business case varies considerably depending on electricity prices and consumption patterns. Therefore, you should be realistic: the payback period is often around 5–7 years, especially if you do not participate in the system service market. The expected battery life is stated as 10–15 years.

It is often advantageous to clearly describe what the solution should deliver in two areas: 1) risk reduction in the event of failure (operational and animal welfare) and 2) daily optimization (operational economy). When the two areas are mixed together, expectations can easily become skewed.

Common obstacles to backup power for agriculture and how to avoid them

Most projects fail not because of the technology, but because of scope, dimensioning, and operation. If you address the typical pitfalls early on, the solution will be both more robust and easier to get approved.

  • Incorrect dimensioning: Systems that are too small cannot cover actual peaks; systems that are too large become unprofitable.
  • Compatibility: The battery and inverter must be correctly matched and able to communicate, otherwise the system may fail when needed.
  • Temperature: Cold reduces capacity, heat accelerates aging; location and design must suit the environment.
  • Documentation and approvals: Deficiencies prior to commissioning can cause operational and insurance problems.
  • Generator operation: Without monthly testing and maintenance, there is a high risk that the generator will not start when needed.

A simple, practical approach is to compile the requirements in a brief "operating plan" for emergency power: who responds in the event of a failure, which circuits are prioritized, how is the solution tested, and where is the documentation located. This makes backup power for agriculture a concrete contingency plan rather than a component that one hopes will work.

FAQ about backup power for agriculture

  • What is backup power for agriculture? Backup power for agriculture is emergency power or buffer capacity that keeps critical processes running during power outages.
  • Which functions are typically critical in the event of a power failure? Often ventilation, milking systems, feeding systems, cooling systems, water pumps, and in some cases heating.
  • What are the advantages of battery energy storage systems (BESS) for backup power in agriculture? Very fast switching (milliseconds) and the possibility of daily operational optimization such as peak shaving and storage of solar power surpluses.
  • When does a generator make the most sense? During prolonged power outages, because the generator can supply power continuously as long as there is fuel.
  • What is a hybrid backup power solution for agriculture? A combination of a battery and a generator, where the battery handles immediate outages and the generator can take over during longer outages or charge the battery.
  • What do we need to have in place before commissioning? Correct registration, anti-islanding when connecting to the grid, fire protection/location, and all documentation in place before the plant is put into permanent operation.

Contact us

Do you have questions or need advice? Our experts are ready to help you.

Contact support

If you would like to contact support, please call +45 35 153 123 or send an email to support@xolta.com.

Contact sales