CO2-neutral energy storage has become a key element in Denmark's path towards significant emission reductions by 2030 and full CO2 neutrality by 2050. The concept covers several technologies that can store energy without net CO2 emissions over an energy cycle – but requirements, economics, and risks vary significantly. For businesses and public sector actors, this typically involves compliance, investment security, and operations; for private individuals, it is more often a matter of understanding what "CO2-neutral" actually means and which solutions are best suited to their needs. Here, we review definitions, frameworks, technologies, and pitfalls so that you can make informed decisions.
CO2-neutral energy storage is used as a collective term for technologies and systems that can store energy without net greenhouse gas emissions over a given energy cycle. In practice, you should therefore always ask: What is the system boundary, and how are net emissions documented? There are both narrow and broad interpretations:
This means that "CO2 neutral" does not automatically follow from the technology itself. It depends on the energy source, operation, and, in some cases, regulatory documentation requirements. As a decision-making aid, it can be useful to distinguish between whether the solution primarily moves energy in time (e.g., batteries and thermal storage), moves energy across sectors (e.g., PtX), or handles CO2 directly in the value chain (CCUS).
Denmark's 2020 climate law commits to a 70% reduction in greenhouse gas emissions by 2030 compared to 1990 and full CO2 neutrality by 2050. In the same strategic direction, integrated solutions are highlighted, where electrification, green hydrogen, PtX, and CO2 capture and storage work together.
At the same time, renewable energy accounted for 81% of Denmark's electricity production in 2022, and Denmark is expected to achieve 100% renewable electricity by 2030. When a larger proportion of electricity and energy comes from variable sources such as wind and solar, energy storage becomes a critical function for managing variability and supporting the link between electricity, heating, and transportation. For you, this typically means that energy storage does not stand alone: it must fit into your supply strategy, your electricity purchase agreements, and your requirements for stable operation.
Denmark has established frameworks for permanent CO2 storage and support schemes that influence which projects can be realized. In practice, this means that the project's "CO2 neutrality" must often be explained in administrative and auditing language—not just in technical language:
If you are considering a project along these lines, it is often crucial to clarify early on what documentation requirements and conditions are associated with access to funding, and how they affect design choices, contracts, and scheduling.
At EU level, the Renewable Energy Directive II (RED II) is central. For renewable fuels of non-biological origin (RFNBO) – including green hydrogen produced via electrolysis – sustainability criteria and a requirement for at least a 70% reduction in greenhouse gas emissions compared to fossil alternatives apply in order to be recognized as CO2-neutral in this framework.
At the same time, there has been regulatory debate about definitions (including whether the requirement should be a 100% reduction), which makes it important to work with documentation and stay up to date when designing projects. In practical terms, you should therefore ensure that your internal decision-making basis clearly distinguishes between technical feasibility (that it can be done) and regulatory recognition (that it counts as CO2-neutral in the relevant scheme).
Power-to-X converts electricity into energy carriers such as hydrogen and synthetic fuels/chemicals that can be used in sectors where direct electrification is difficult and that can be stored for later use. Electrolysis is the core process: water is split into hydrogen and oxygen using electricity. When the electricity comes from renewable energy, "green hydrogen" is produced.
If you consider PtX to be CO2-neutral energy storage, it is often useful to clarify three specific questions: What will the hydrogen be used for (internal consumption or sale), how flexible can the plant operate in relation to electricity prices and production, and what requirements are there for documentation of the origin of the electricity within the framework you are working under?
There are different types of electrolysis. Alkaline electrolysers will be the most mature and cost-effective (capital costs €242–388/kW) in 2025, while PEM systems will be more expensive (€384–1,071/kW). A significant operational challenge is flexibility: alkaline plants have challenges with frequent stop/start cycles, which can be a disadvantage with highly variable wind and solar production. This should therefore be included in your assessment of whether the plant should primarily run stably or whether it should be able to follow fluctuations in production and prices.
CCUS combines CO2 capture, transport, and either utilization or permanent storage. In Denmark, the focus is primarily on permanent geological storage, including under the North Sea. Danish regulations require detailed measurement, reporting, and monitoring, including CO2 marking for traceability, as well as strict safety requirements for transport and storage.
In practical terms, this means that implementation is not just a matter of choosing the right technology: it also requires access to support schemes, relevant transport infrastructure, and contractual agreements across the value chain (capture, transport, storage). When assessing CCUS in a CO2-neutral energy storage context, it is therefore often crucial to get the interfaces right: Who is responsible for what, what requirements apply to measurement and reporting, and how are operations and incidents handled throughout the chain? Ørsted's Kalundborg Hub is mentioned as the first major CCUS investment with a 20-year agreement, expected to start in 2026.
Thermal energy storage stores heat in, for example, water or other materials and can be used for heating/cooling or industrial processes. Denmark has specific experience with district heating and heat pumps. As a decision parameter, it is often a matter of clarifying whether the need is for short-term balancing (hours/days) or seasonal storage (months), and how the storage facility is connected to existing production and consumption.
A key example is Marstal on Ærø, which has a large solar heating plant and seasonal storage: 33,365 m² of solar collectors supply approx. 28,000 MWh of thermal solar energy annually, stored in, among other things, a 75,000 m³ pit seasonal storage facility. The temperature varies from approx. 80–85°C in summer to approx. 10°C in winter. Since 1994, Marstal District Heating has gradually switched to 100% renewable energy with contributions from, among other things, solar, wood chips, and heat pumps. This example illustrates that thermal CO2-neutral energy storage can make sense when there is a clear heat consumer and operations that can be planned over a longer period of time.
Batteries (often lithium-ion) are typically used for short-term storage (2–4 hours). In 2025, average energy storage costs are estimated at $200–400/kWh, depending on technology and scaling. Batteries are well suited for frequent cycling and rapid response, but degradation and safety are key parameters. In practice, you should therefore assess what the battery is specifically intended to solve: peak load, production smoothing, or rapid regulation. This choice affects both operational requirements and life expectancy expectations.
Second-life EV batteries (batteries from electric cars, typically phased out at 70–80% capacity) can be used for stationary storage, where the requirements are different than in a car. This can support a circular battery economy, but requires robust data systems to assess battery condition and safety. Costs after refurbishment are often quoted at less than $100–150/kWh, while new tier-1 systems are quoted at over $250/kWh. For you, it may be relevant to clarify how performance and safety are documented and how to ensure consistent operation when the batteries have different histories.
The economics depend on technology, scale, and application. Green hydrogen has a clear "green premium" compared to gray hydrogen. Batteries have fallen in price over time but still represent a significant investment. For BESS projects in Denmark, analyses indicate that projects can achieve positive returns, but with modest profitability and a payback period of around 12.75 years under current market conditions.
If you want to use the assessment in a decision-making process, it can be helpful to break down the economics into: (1) the investment, (2) operating costs and operating requirements, and (3) revenues or savings from the specific application. This also makes it easier to see which assumptions are deal breakers (e.g., connection requirements, operating profile, or documentation) and where there are opportunities for action (e.g., optimized operations or clearer agreements in the value chain).
For companies, revenue stacking—revenue from multiple uses of the same facility—can be crucial, e.g., by combining storage with participation in flexibility services such as demand response. The potential for synergies from participating in multiple markets is demonstrated in analyses of residential batteries with improvements of 3.7–12.0% over baseline scenarios (example from Sweden). This does not change the fact that it requires careful prioritization: multiple uses can also mean more operational requirements, more contracts, and greater complexity in management.
Regardless of the technology, it is advantageous to work systematically with risks early on. This reduces both schedule risk and operational risk, and makes it easier to document that the solution is robust. Below are the typical pitfalls that you should have a plan for before moving forward:
As a next step, it may be useful to convert the points into a short "ready-to-decide" list: Which risks can you accept, which ones need to be reduced through design and procedures, and which ones require that the prerequisites (e.g., infrastructure or documentation) are in place before the project makes sense?
Do you have questions or need advice? Our experts are ready to help you.
If you would like to contact support, please call +45 35 153 123 or send an email to support@xolta.com.