Power tariffs

Power tariffs change the way you (and you as a private customer) pay for the transmission of electricity in the grid. Whereas grid tariffs previously largely followed energy consumption (kWh), there is now a clearer price signal for how much power (kW) is used at any one time. The aim is to reduce the load during peak hours when many people are using electricity at the same time, thereby reducing the need for expensive grid expansions. Here is a practical overview of what power tariffs are, how they are typically calculated, and what you can do to manage them in your operations and everyday life.

Power tariffs explained: The difference between power (kW) and energy (kWh)

Energy (kWh): Your total consumption over time. This corresponds to the total amount of electricity used during a period.

Power (kW): How much electricity you use at any given time. It's about "how fast" you draw power when several things are running at once.

The difference is crucial in practice: You can use the same amount of energy to charge an electric car, for example, but if charging takes place over a few hours, it requires higher power during those specific hours. Power tariffs therefore focus on the hours when consumption peaks, because it is these peak loads that place demands on the dimensioning of the electricity grid.

As a rule of thumb, you can think of it this way: kWh determines "how much," while kW determines "how hard at once." Power tariffs are largely a payment for the latter.

Why are power tariffs being introduced?

Power tariffs are being introduced in response to increasing pressure on the electricity distribution grid from increased electrification, e.g., electric cars, heat pumps, and electric heating. When many people use a lot of electricity at the same time – typically during peak cooking times – the grid must be dimensioned for the highest peak loads. This drives the investment need in the electricity grid, which is estimated at DKK 49-57 billion by 2030. By getting more people to spread their consumption, the investment need can be reduced, and there are calculations that point to a potential reduction of around DKK 8 billion over a seven-year period if consumers respond to price signals.

The key point is that the grid must be able to handle the "worst hour." Power tariffs are an attempt to make this correlation clearer in the price, so that it becomes more attractive to avoid having many large consumers consume at the same time.

Power tariffs in Denmark: Legal requirements and basic principles

Under the current framework, tariffs must be cost-reflective, reasonable, objective, and non-discriminatory. At the same time, they must, to the greatest extent possible, send signals about the efficient use and development of the electricity grid. The EU's Electricity Market Directive requires that tariffs reflect actual costs and support the overall efficiency of the system through price signals that are transparent and non-distortive.

For you as a customer, this means in practice that power tariffs must be explainable and documented, and that network companies must use a model that can be justified on the basis of network costs and load. If something seems unclear, it is therefore relevant to ask how the measurement basis and price structure are constructed.

There is also a requirement that all network companies must have implemented a power tax as part of their pricing structure by January 1, 2027. Implementation will take place gradually in the run-up to this date.

How power tariffs relate to Tariff Model 3.0

Tariff Model 3.0 (approved as an industry standard) describes how electricity network tariffs are structured. The model works with four main components:

It is worth viewing the components as separate "lines" in the bill: some are fixed (regardless of usage), while others are affected by consumption patterns and power peaks.

  • Fixed subscription: A fixed amount.
  • Customer-specific fee: Covers measurement and administration, among other things.
  • Energy tariff: Payment based on consumption in kWh.
  • Power tax: Payment based on maximum power requirement in kW.

Overall, this means that you cannot simply "save your way out" of the net tariff by using fewer kWh. With a power tax, it becomes just as important to avoid short periods of very high consumption.

The model is based on a "waterfall principle," where costs are distributed according to voltage level and the costs generated by customer groups. This helps to ensure that low-voltage customers do not pay for costs driven by customers at higher voltage levels.

How power tariffs are calculated in practice (typical model)

A common method is for the network operator to measure the two highest hourly values in a month – from two different days – take the average and multiply it by an energy price. This makes it more important financially to avoid very high peaks than to reduce consumption slightly over many hours.

For you, this means that a single "unfortunate" spike can affect the bill, but at the same time, the model seeks to avoid a completely extraordinary day alone becoming decisive. This makes it relevant to work with both behavior and management: You will typically get the most out of identifying the situations that create peaks and dealing with them specifically.

An illustrative example of the calculation logic: If a household has 8 kW as the highest hourly value on one day and 7.5 kW on another day, the calculation basis becomes (8 + 7.5) / 2 = 7.75 kW. Multiply this by a given power price to obtain the monthly power payment. The important thing is the mechanism: lower peaks result in lower payments.

In practice, the next step is often to ask: What triggers the two highest hourly values? Is it electric car charging combined with cooking, heat pumps, and electric water heaters, or is it a process step in production that coincides with cooling, ventilation, and other equipment? Once the cause is known, you can typically plan your way out of a large part of the fluctuations.

Time-differentiated power tariffs: Low load, high load, and peak load

For private customers and small businesses using low voltage, power tariffs are typically time-differentiated. This means that the same power (kW) can cost different amounts depending on the time of day when it is consumed. The day is often divided into:

  • Low load: 12:00 a.m. to 6:00 a.m.
  • High traffic: 6 a.m. to 5 p.m. and 9 p.m. to midnight
  • Peak load: 5-9 p.m.

These time windows serve as a practical "planning framework": if you can shift flexible consumption to off-peak hours, you reduce the risk of incurring expensive peak loads while also relieving pressure on the grid when it is under the most strain.

In addition, there is often seasonal differentiation between summer (April-September) and winter (October-March), because the grid is generally more heavily loaded in winter. There are examples of very significant price differences between summer and winter during peak load periods, with winter prices being considerably higher.

This makes it important to be extra mindful during the winter months when several large loads coincide. For many, it is less about "saving electricity" and more about avoiding many electricity consumers using power at the same time.

Electricity tariffs for businesses: Who is most affected and why?

Larger business customers already have mandatory power payments in many cases. For them, power tariffs can be particularly relevant because production equipment, processing plants, refrigeration/freezing, and charging can often create high simultaneous loads.

Typical challenges arise when several large consumers start up at the same time, or when operations have clear "peak periods" during the day. It can also be planned routines that unknowingly create peaks, e.g., plant start-up, simultaneous defrost cycles, or charging of electric fleets always starting at the same time.

An example of the connection between peak and payment: If a company pays per kW for power, a reduction in the measured peak (e.g., by distributing load or using flexibility) will directly reduce the power payment.

If you are working with TCO and operational stability, it is often advantageous to view power tariffs as an operational parameter in line with other capacity constraints: When the peak is under control, costs become more predictable and the risk of unwanted "peak situations" decreases.

Power tariffs: What can you do to reduce power peaks?

Power tariffs only work as intended if consumers understand the price signal and are able to respond. Experience shows that price signals alone do not always change behavior—it often requires information, feedback, and technology.

A practical approach is to work in three steps: 1) get an overview of when the peaks occur, 2) identify which loads drive them, and 3) choose the least intrusive measures first, before investing in more advanced solutions.

  • Load shifting: Shift consumption away from peak loads (typically 5-9 p.m.) where possible. This could involve, for example, scheduling charging, heating, or other energy-intensive tasks for off-peak hours, if operations allow.
  • Feedback on consumption: Use consumption data to identify the times when peaks occur. Look especially for recurring patterns: If the peak occurs again on the same days of the week or at the same times, it is often possible to plan around it.
  • Automatic control: Controlling things like electric car charging, heat pumps, and other big loads can reduce simultaneity. This usually means setting priorities, start delays, or power cuts so the load is spread out over several hours.
  • Batteries and storage: Storage can shift energy consumption over time, thereby reducing demand from the grid during peak periods. This can be particularly relevant if you have recurring peaks that are difficult to shift without affecting comfort or operations.

Regardless of the measures you choose, it is beneficial to follow up: Once you have changed a routine or set up a control system, check whether the highest hourly values are actually falling. Power tariffs typically reward precisely this type of targeted peak management.

Power tariffs, smart meters, and data quality: Prerequisites and pitfalls

Power tariffs require metering, typically via smart meters that can record consumption hour by hour. Challenges may arise if meters do not support the necessary time differentiation or if data transfer fails, as this may lead to billing errors. At the same time, clear communication is important: if customers do not understand how power tariffs are calculated, this may create uncertainty and reduce the effectiveness of the scheme.

As a customer, you can reduce uncertainty by working systematically with data: Ensure that you have access to hourly values, that you can link them to specific events (e.g., shifts, production peaks, or charging), and that internal managers know what needs to be monitored. If the bill changes significantly, it is also a good idea to compare it with the two highest hourly values in the period to see if the change can be explained by individual peaks.

Power tariffs in local communities: Local collective tariffing (LKT)

A recent development is local collective metering, which makes it possible to meter a local association collectively via a "virtual metering point." Here, the power tariff is calculated based on the group's total maximum power consumption rather than the sum of individual peaks. The model is linked to frameworks for local energy communities and requires renewable energy production (e.g., solar cells) with a minimum registered level.

In practice, it is important to understand the difference between individual and collective peaks: if several participants have their peaks at different times, the total peak may be lower than if everyone peaked at the same time. Therefore, coordination and insight into common load patterns become key when assessing whether a collective model makes sense in everyday life.

Power tariffs and solar cells: Self-producers and feed-in tariffs

Parallel to power tariffs for consumption, changes are seen for self-producers (typically solar cells). From 2026, more differentiated feed-in tariffs and self-producers' contributions will be introduced, based on cost accuracy: feeding into the grid can generate grid costs (e.g., operation and grid losses), and tariffs seek to reflect this impact more proportionally.

For self-producers, this means that it is not only the consumption side that is becoming more "time and effect sensitive." It will be relevant to keep track of when production is sent to the grid and when it can be used directly or stored, depending on the applicable tariffs. The point is not that one solution fits all, but that tariffs increasingly reward planning and management of both consumption and any feed-in.

Power tariffs: How we can help you at XOLTA

Power tariffs make it more important to know and manage your power peaks – both in private homes with electric cars/heat pumps and in businesses with energy-intensive installations. We help translate tariffs into concrete operational measures so that you can prioritize the measures that make sense in practice.

We typically start by establishing a common basis for decision-making: Which areas drive costs, which can be moved, and which are tied to operations? We then draw up a plan that fits your everyday life and your technical setup.

  • Analysis of power peaks: We identify when and why the peaks occur.
  • Flexibility plan: We assess load shifting and automation needs.
  • Integrity and operation: We take responsibility for the connection between management, installation, and stable operation.

The goal is a solution where power tariffs become manageable in practice: clear priorities, fewer surprises, and operations that are easier to manage, follow up on, and document.

FAQ about power tariffs

  • What are power tariffs? A tariff model where payment depends more on your maximum simultaneous electricity consumption (kW) – not just your total consumption (kWh) – often with time-differentiated prices.
  • How is the power tariff typically measured? Often based on the two highest hourly values in a month from two different days, with the average used as the basis for the power payment.
  • When is the electricity grid typically most heavily loaded in power tariffs? Peak load often occurs between 5 and 9 p.m., when many people are using electricity at the same time, and this is when the price signal is typically strongest.
  • When must all network companies have introduced power tariffs? By January 1, 2027, network companies must have implemented a power tariff as part of their pricing structure.
  • Why are power tariffs being introduced? To reduce simultaneous peak loads and thus reduce the need for extensive grid expansions, which would otherwise require major investments towards 2030.
  • What can I/you do to be less affected by power tariffs? Reduce power peaks by shifting consumption away from peak loads, using consumption feedback, and considering automatic control and/or storage where relevant.

Contact us

Do you have questions or need advice? Our experts are ready to help you.

Contact support

If you would like to contact support, please call +45 35 153 123 or send an email to support@xolta.com.

Contact sales