Emergency power

Emergency power is a solution that ensures that selected or all electrical functions continue to operate when the public power grid fails. In Denmark, the security of supply is normally high, but interest in emergency power is growing in line with increased focus on preparedness, extreme weather, and the risk of technical or digital incidents. For both businesses and private individuals, it is a matter of choosing the right technology, having it installed safely, and testing it regularly. Here, we review what emergency power is, what solutions are available, and what you should clarify before investing, so you avoid a solution that only works "on paper."

What is emergency power and what is the difference between emergency power and backup power?

Emergency power: An independent source of electrical energy that automatically or manually kicks in when the normal power supply is interrupted. The purpose is to keep critical loads running for a period after a failure. This can be anything from lighting and communications to pumps, IT, or access control, depending on requirements.

Backup power: Often used as a synonym, but can be understood more broadly. Backup power can cover longer-term operation and more extensive consumption, e.g., the entire house or a large part of the business. In practice, the difference can mainly be about how much needs to be kept running and for how long.

UPS (uninterruptible power supply): A specific type of solution that provides emergency power with very little or no interruption, while also filtering and regulating incoming power to ensure stability for sensitive equipment. This makes UPS relevant when even short interruptions can cause downtime, data loss, or equipment failure.

Why choose emergency power in Denmark?

Power outages can occur for a number of reasons, including storms and other extreme weather, technical faults, and incidents such as buried cables. In addition, there are modern threats such as cyber attacks and sabotage against critical infrastructure. The consequences vary, but can be serious. When assessing your needs, it makes sense to start with what happens in your operations or everyday life if the power goes out for minutes, hours, or longer.

  • Private: Food waste in the fridge/freezer, cold homes in winter, loss of mobile and internet connection, and risk of damage to the home. Pay particular attention to features that affect safety and comfort: heating, ventilation, and water supply.
  • Businesses and critical operations: Even short-term outages can be problematic for IT, telecommunications, payment systems, and other critical functions. An outage can also have knock-on effects such as production stoppages, process errors, or problems with documentation and access systems.

Common to both private and commercial users is that emergency power is often a trade-off between desired operational continuity and what is practical to establish and maintain. Therefore, you should clarify early on which functions are "critical" and which can be dispensed with during an outage.

Choosing emergency power: UPS, generator, or battery?

There are several ways to obtain emergency power. The choice depends on how quickly you need power (transfer time), how long you need to be able to run (duration), and whether the solution should cover critical circuits or the entire building. It is often advantageous to think in terms of scenarios: What needs to continue immediately, and what can wait?

As a rule of thumb, UPS is relevant when the interruption must be minimal. A generator is relevant when duration is the most important factor. Batteries and solar cell systems may be relevant when you want an electrical solution that can deliver power to the property in the event of a power failure, provided that the system is designed for this purpose.

UPS as emergency power for critical electronics

UPS: Provides power when the supply fails and can allow time for a controlled shutdown. Typically, internal batteries support 10–15 minutes of operation, and in some cases, more battery backup is needed. The practical point is that UPS is not just about "having power," but about protecting equipment and ensuring a controlled process so that data and components are not damaged.

When choosing UPS as your emergency power supply, you should consider what specifically needs to be protected (servers, networks, control systems, payment terminals) and whether the goal is to continue operations or simply to achieve a safe shutdown.

  • Standby UPS: Switches to battery power when problems are detected. Suitable for basic backup where shorter transfer times are acceptable.
  • Line-interactive UPS: Handles power dips better via a transformer. Relevant if you experience variations in the power supply and want to reduce the impact on equipment.
  • Online UPS: Double conversion provides high protection and zero transfer time to battery for sensitive equipment. Typically used when stability and continuity are more important than simplicity.

Regardless of the type, you should ensure that the UPS is dimensioned for the actual load and that the batteries' operating time matches your needs. A UPS that can only supply power for a few minutes may still be the right solution if it is intended as a bridge to a controlled shutdown or as a transition to another emergency power source.

Generator as emergency power supply during prolonged power outages

Generators: Often used when power is needed for many hours or days, provided there is sufficient fuel. Modern emergency generators typically start in less than 10 seconds, but there will still be a start-up period. In practice, this means that a generator is rarely used on its own if you have equipment that cannot tolerate interruptions. Here, it is often combined with a solution that covers the "gap" during start-up.

Before choosing a generator as an emergency power source, you should clarify where the generator will be located, how fuel will be handled, and who will be responsible for operation and ongoing monitoring. Practical considerations often determine whether a solution will work in everyday life.

  • Gasoline generator: Easily accessible and easy to start in cold weather. Disadvantages may include shorter fuel shelf life, higher consumption, and increased fire hazard.
  • Diesel generator: More fuel-efficient and suitable for longer operation. Disadvantages may include more noise, heavier engines, and the need for ongoing maintenance.
  • Gas generator: Runs on LPG and emits fewer particles than gasoline and diesel. Natural gas versions can be connected to a fixed gas line, but are dependent on the gas supply.

Safety: Generators require proper installation with a transfer switch/ATS to prevent backflow to the grid, which can be dangerous for electrical workers. It is also an important part of ensuring that the switch between grid and emergency power is controlled so that the installation is not exposed to inappropriate loads.

Battery and solar cell system as emergency power (off-grid/island operation)

Solar cell battery systems: Can function as emergency power if the system is designed for off-grid operation (island operation), enabling it to produce and supply power independently of the grid in the event of a power failure – as long as the sun is shining and/or there is power in the battery. The key factor here is the design: A standard solar cell system cannot automatically supply power to the house in the event of a grid failure if it is not built for island operation.

Hybrid inverter and backup components: A hybrid inverter system can be combined with, for example, a backup box and automatic transfer switch (ATS) so that critical loads can be supplied when the grid fails. In practice, you should decide which circuits should have emergency power and how they should be separated from the rest so that the system is not overloaded during an outage.

Important restriction: The system may supply emergency power to the specific property, but it may not supply neighbors or an entire area in the event of a grid failure. This is a crucial clarification when planning the scope and connection.

Switch to emergency power and load shedding: how to keep the most important functions running

Emergency power transfer (ATS): An automatic grid transfer switches from public supply to emergency power when an outage is detected. If automatic start-up is not possible, a manual switch is used. The big difference in practice is whether you can be present and take action when the outage occurs, or whether the solution must be able to function without staffing.

Load shedding: Non-essential loads can be automatically disconnected to ensure that the available emergency power is prioritized for critical systems. This reduces the risk of overload, which can cause the system to fail. For many, this is the key to a robust solution: you get power to the most important things, instead of trying to supply everything and risking losing it all.

A practical way to approach this is to define a "critical group" (e.g., communication, control, and necessary lighting) and a "comfort group" (e.g., other power outlets), so that you have agreed on the priorities in advance.

Rules and safety regarding emergency power in Denmark

Electrical installations in Denmark are based on international and European standards (IEC 60364/HD 60364) and the Danish DS/HD 60364 series. In addition, technical requirements apply to electricity generation plants connected to the grid, and the requirements may vary depending on the expected operating time. For you, this means that requirements and documentation should be included early in the project so that the solution is both safe and legal to put into operation.

  • Grid connection: Clarify early on whether the solution should only supply emergency power in the event of a failure, or whether it should also be able to run in parallel with the grid. This affects the choice of components and the overall connection.
  • Operating time: Facilities that run in parallel with the grid for less than five minutes per month are subject to fewer requirements than facilities that are expected to be used more. This makes it important to plan both testing and operating patterns to match the purpose.
  • Environmental conditions: Emergency generators may require environmental approval, especially if they are expected to be used for more than emergency power and limited test operation. Therefore, you should be aware of when and how the generator will actually be used.
  • Electrical safety: Safe installation is essential, and components such as fuses/circuit breakers protect against overload and short circuits. Also consider clear labeling and access so that operation and service can be performed correctly.

CE marking: For relevant components, CE marking is important, but it is not a quality mark. It indicates that the manufacturer declares compliance with relevant requirements. In practice, you should still ensure that the design, installation, and documentation of the solution are suitable for the application.

Dimensioning and operation of emergency power: how to avoid false security

Private: Start by listing the appliances that need to be able to run during a power outage and note their power (W/kW) and phase/voltage (1-phase/230 V or 3-phase). Emergency power systems connected to the mains must be 3-phase. Many homes also have 3-phase consumers such as cookers or washing machines. Therefore, clarify whether the goal is to keep individual critical functions running or whether there is a need to cover multiple circuits.

Businesses: A targeted risk and vulnerability assessment should form the basis. Draw up a load prioritization list and clarify acceptable downtime before final dimensioning. Ensure that the list reflects actual operations: Which systems must not stop, and which can be restarted later without unacceptable consequences?

Pitfalls: Undersizing can mean that emergency power cannot deliver the necessary power. Oversizing can make the solution unnecessarily expensive in terms of investment and operation. Regardless of the technology, emergency power requires proper installation and ongoing maintenance to function when needed. A good decision point is therefore to assess both power requirements and duration together, so that you do not end up with high power for a short period of time when the actual need is for moderate power for a longer period (or vice versa).

Testing and maintenance of emergency power in practice

Maintenance is crucial to ensuring that emergency power works in practice. A solution that is never tested can give a false sense of security. Therefore, plan regular routines for testing, logging, and follow-up so that errors are detected before a real incident occurs.

  • UPS: Weekly short-circuit testing can ensure that the batteries are in good working order and can handle the load. At the same time, make sure that testing is carried out in a way that does not cause unnecessary interruptions to critical systems.
  • Generator: Monthly or quarterly manual testing, including testing of auto-start and running without load first. Annual testing with load confirms capacity under realistic conditions. This is typically where you discover problems with starting, switching, or stable operation.
  • Generator battery: A large proportion of starting faults are related to the battery. Check the fluid level, clean and secure terminals, and regular start-up.

Regardless of the solution, you should ensure that those responsible for operations are familiar with the tests and services. You should also document what has been tested and what the results were so that you can monitor developments over time and respond if performance changes.

FAQ about emergency power

  • What is emergency power? Emergency power is an independent power source that takes over completely or partially when the normal power supply is interrupted, so that critical functions can continue.
  • What is the difference between emergency power and backup power? Emergency power typically focuses on vital functions and often shorter outages, while backup power can cover longer-term operation and broader consumption, e.g., the entire house or a large part of a business.
  • How quickly does a UPS take over as emergency power? UPS solutions can provide instant power with very short transfer times, and online UPS can provide zero transfer time to battery for sensitive equipment.
  • Why does an emergency generator need an ATS/transfer switch? To prevent backflow to the power grid, which can be dangerous for electrical workers, and to ensure correct and safe switching in the event of a power failure.
  • Can a solar power system provide emergency power during a power outage? Yes, if the system is designed for off-grid operation (island operation), it can supply power independently of the grid as long as there is sunlight and/or power in the battery.
  • Why is maintenance important for emergency power? Without regular testing and servicing, you risk the solution not working in a real emergency – especially for generator start-up, where the battery is often a typical source of failure.

Contact us

Do you have questions or need advice? Our experts are ready to help you.

Contact support

If you would like to contact support, please call +45 35 153 123 or send an email to support@xolta.com.

Contact sales