Supplementary heat sources

Supplementary heat sources are additional heating systems that support—but do not replace—the building's primary heating installation. The goal is to reduce heat consumption by utilizing alternative energy sources, allowing you to lower your heating costs while reducing CO₂ emissions. For both private and professional players, the choice is typically about finding the right combination of technology, comfort, and regulatory compliance. Here you will find a comprehensive overview of the options, requirements, and typical pitfalls, so you can make a more informed choice.

What are supplementary heat sources, and what are they used for?

Supplementary heat sources provide part of the building's heating requirements alongside the main heating system. This is relevant if you want to reduce the load on an existing heating system or if you want to utilize renewable energy sources where practical. In practice, the supplementary solution often works best when used specifically during periods or in rooms where the need is greatest, rather than as an "all-in-one" replacement.

Purpose: To achieve lower heat consumption, potentially lower heating bills, and a reduction in CO₂ emissions. To achieve an effect in everyday life, you should also consider how the supplementary heat source should be used: Should it cover a fixed area (e.g., living rooms), relieve peak loads, or ensure more stable comfort when outdoor temperatures fluctuate?

Typical supplementary heat sources and what you should choose based on

There are several widely used supplementary heat sources, which are typically chosen based on the type of building, heating installation, and purpose of the investment. Below is an overview of the most relevant types and their key features. When comparing solutions, it is a good idea to focus on three practical questions: What heating needs must be met (space heating or hot water), how does the solution fit in with the existing system, and what requirements apply to documentation and registration?

Air-to-air heat pump as a supplementary heat source for space heating

An air-to-air heat pump is a supplementary heat source that provides space heating but does not produce hot water. Coverage: It can typically cover up to 70% of your space heating needs. Practical implications: It can be used to supplement gas, oil, or electric panels, for example, but you will still need a solution for hot water.

To use the solution appropriately, you should consider where the heat actually needs to be delivered. An air-to-air heat pump is typically best suited when it can heat the rooms you spend the most time in and when air circulation can distribute the heat. It is therefore relevant to clarify whether the supplementary heat source should support one area effectively or whether you expect the same effect throughout the building.

Solar heating as a supplementary heat source for hot water and space heating

Solar heating systems are a sustainable supplementary heat source with low operating requirements. They can be used for hot water and space heating. This makes solar heating relevant if you want to use solar energy to reduce heat consumption in your primary installation.

In practice, you should decide what the solar heat is primarily intended to support: hot water, space heating, or both. This will determine how the supplementary heat source is integrated into the building's daily operation and how you can best achieve a stable heat supply when solar radiation varies. A clear definition of the purpose also makes it easier to document the solution and avoid misunderstandings about what it can and cannot contribute.

Domestic hot water heat pump as a supplementary heat source for domestic hot water

A domestic hot water heat pump can be used as a supplementary heat source for hot domestic water. Characteristics: It recovers moisture heat and is particularly relevant in houses without a ventilation system. It is therefore typically used as a supplement when the focus is on hot water rather than space heating.

If your primary challenge is energy consumption for hot water, it may make sense to keep room heating unchanged and focus your efforts on domestic hot water. This makes the decision easier because you can evaluate the solution based on a specific need: the amount of hot domestic water, your comfort requirements, and how the installation fits in with the existing technology in the building.

Wood-burning stove as a supplementary heat source with special rules

Wood-burning stoves can serve as a supplementary heat source in certain situations, but there are clear rules governing their use. Rule-based calculation: When a wood-burning stove is combined with electric heating or heat pumps, the stove is calculated as 15% of the estimated energy requirement for the room. In rooms with only a wood-burning stove, it can be calculated as 100% for that room.

Compatibility: Wood-burning stoves must not be included in rooms with water-based central heating, but are fully included in rooms without any other heat source. This means that the same wood-burning stove can have different significance in calculations depending on how the rest of the heating is set up.

If you are considering a wood-burning stove as a supplementary heat source, it is important to distinguish between "practical use" and "calculated significance." The daily experience of extra heat may be obvious, but energy calculations and documentation follow the fixed rules for inclusion. Therefore, you should clarify early on which rooms the wood-burning stove is intended to cover and whether the room already has water-based heating, so that you avoid a solution that cannot be included as expected in the energy label or registration.

Rules for supplementary heat sources: energy label, A2020, and BBR

Regulations play a key role because supplementary heat sources can affect both energy calculations and building documentation. In practice, this means that the solution must be correctly described, correctly registered, and correctly processed in the calculations underlying the energy labeling. A good rule of thumb is to ensure consistency between what is installed, what is registered, and what is assumed in the calculations.

  • Energy label A2020: Danish homes must have supplementary heat sources – typically solar heating, heat pumps, or solar cells – in order to meet the A2020 standard.
  • BBR registration: Supplementary heating installations must be registered in the Central Building Register, where both the installation type and energy source are documented.
  • Energy labeling rules: There are special rules governing how supplementary heat sources (e.g., wood-burning stoves) are treated in the energy labeling scheme.

To avoid unnecessary corrections later, you should be specific in your documentation: What type of supplementary heat source is installed, what is the energy carrier, and what is its role in the building (space heating, hot water, or both)? This makes it easier to obtain a correct registration and an energy label that reflects the actual installation.

Supplementary heat sources and economics: what can they typically contribute?

Supplementary heat sources can save money on heating bills while reducing the impact on the climate. How this value is realized depends on the building's operation and the solution chosen. It is typically less about one "magical" technology and more about how the supplementary heat source is used in conjunction with the primary heating system.

Therefore, consider what you specifically want to achieve: Do you want to reduce consumption during certain periods, reduce dependence on a particular energy source, or make heat supply more flexible in daily operations? The points below describe the most common ways in which a supplementary solution can contribute.

  • Reduced consumption: An additional heat source can reduce consumption on the existing heating system.
  • Energy carrier switch: It may be possible to switch from expensive energy carriers such as oil, natural gas, or wood pellets.
  • Operating profile: In the long term, the solution may have lower operating requirements, depending on the type of installation.

Specific price information is not set out in regulations, and costs depend on the type of installation and the size of the building. Therefore, the assessment should be based on your specific property and needs. This can be done, for example, by clarifying which parts of the heating requirement the supplementary heat source is to cover and what operating habits are expected in practice. This will make the economic assessment more robust and less based on assumptions.

Common pitfalls with supplementary heat sources and how to avoid them

The typical risks rarely concern the idea of supplementary heat sources itself, but rather the choice of solution, combinations, and correct registration. Many problems arise when expectations regarding function (what it can deliver) do not match the requirements for documentation (how it can be included). Use the list here as a practical checklist before you make your decision.

  • Regulatory complexity: Wood-burning stoves are strictly regulated in energy calculations. Incorrect calculations or registrations can affect the energy label.
  • Compatibility: Certain combinations may be incompatible in calculations, e.g., wood-burning stove together with water-based heating.
  • Lack of hot water: Air-to-air heat pumps provide space heating, but not hot water.
  • Outdated equipment: Wood-burning stoves older than January 1, 2003, must be proposed for either demolition or replacement with a newer model.
  • Installation and documentation: Correct installation and BBR registration are mandatory for legality.

If you want to reduce the risk even further, it is a good idea to summarize your clarifications in a brief decision basis: Which rooms/consumption should be covered, what role does the supplementary heat source play in the operation, and how should it be registered? This makes it easier to make the right choice the first time and avoid subsequent changes in both installation and paperwork.

Supplementary heat sources in practice: who uses them and why?

Both private individuals and professionals work with supplementary heat sources, but their intentions and criteria for success may differ. What they have in common, however, is the need for a solution that suits the building's technical setup and can be properly documented. Below are the typical focus areas that often guide the decision.

  • Private homeowners: Typically focused on saving on heating bills, making better use of energy, and ensuring that upgrades match the heating needs of the home.
  • B2B (installers, energy consultants, construction managers): Typically focused on proper regulatory compliance, documentation (BBR), and handling special calculation rules, especially for wood-burning stoves.

Regardless of the target group, it is crucial to choose a supplementary heat source that is compatible with the building's other heating installations and the requirements that apply to registration and energy labeling. A practical approach is to start with the need (space heating or hot water), then check compatibility with existing heating, and finally ensure that the documentation can keep up. This creates a more predictable process from idea to operation.

FAQ about supplementary heat sources

  • What does "supplementary heat sources" mean? These are additional heating systems that supplement—not replace—the building's main heating system.
  • How much can an air-to-air heat pump cover? It can typically cover up to 70% of your space heating needs, but it does not produce hot water.
  • Do supplementary heat sources need to be registered? Yes, supplementary heating installations must be registered in the BBR with the installation type and energy source.
  • How is a wood-burning stove included in energy calculations? When a wood-burning stove is combined with electric heating or heat pumps, it is included as 15% of the calculated energy requirement for the room. In rooms with only a wood-burning stove, it can be included as 100% for the room in question.
  • Can a wood-burning stove be included in rooms with water-based central heating? No, wood-burning stoves may not be included in rooms with water-based central heating.
  • What applies to old wood-burning stoves? Wood-burning stoves older than January 1, 2003, must be either demolished or replaced with a newer model.