Thermal energy storage

Thermal energy storage involves storing heat or cold when energy is cheap or readily available and using it again when demand is higher or prices are higher. For Danish companies, district heating companies, and public sector players, the technology is particularly relevant when you want to utilize surplus heat, manage seasonal fluctuations, and create more flexible operations. At the same time, thermal energy storage can work in conjunction with heat pumps, power-to-heat, and load shifting, so that energy is shifted in time without creating new bottlenecks. In this article, we review how the technology works, what solutions are available, and what you should clarify before investing, so that the basis for your decision is practical and reliable.

What is thermal energy storage, and when does it add value?

Thermal energy storage (often abbreviated TES) is a method of storing thermal energy as heat or cold for hours, days, or seasons until the energy can be used when needed. In practice, this means that surplus heat from, for example, industrial processes, solar heat in the summer, or periods of cheap electricity can be stored and used later.

The concrete value arises when you can offset the mismatch between production and consumption. For example, you may have heat available when there is no demand, or you may have a later need where the alternative is more expensive operation. The key is therefore to be able to move energy in time without the solution being limited by too low a temperature, lack of demand, or insufficient discharge capacity. You should clarify early on whether your challenge is primarily about energy volume (MWh), power (kW), or temperature requirements, because this will determine both your choice of storage and integration.

Thermal energy storage can be integrated with several types of energy systems, including combined heat and power (CHP) plants, concentrated solar power (CSP), and power-to-X solutions, depending on your design and operational needs. In practice, it is often the interaction between control, heat exchange, and operating routines that determines whether storage can actually be utilized when needed.

Three main types of thermal energy storage: sensible, latent, and thermochemical

Thermal energy storage technologies are typically divided into three categories. They differ in terms of maturity, complexity, space requirements, and operational requirements. For you, this means that your choice is not only about the storage facility itself, but also about how robust the solution is in everyday operation and how much documentation you can demand before you commit.

Sensitive thermal energy storage, where heat is stored without phase change

Sensitive storage stores heat without phase change, typically in water or rock. It is the most widespread and commercially mature solution and accounts for the majority of existing installations. Water-based storage facilities can be pressurized or unpressurized and are designed as different types of tanks depending on the storage horizon and temperature level.

In Denmark, pond heat storage and large hot water tanks are widely used in district heating for both short-term and seasonal storage. In practice, a well-functioning sensitive storage facility often involves maintaining temperature stratification, minimizing heat loss, and ensuring that input and output occur in a way that supports your desired operation. This makes it relevant to think of storage, heat exchange, and control as a single integrated solution rather than as individual components.

Latent thermal energy storage with PCM when space and energy density are key considerations

Latent storage uses phase change materials (PCM) and is typically seen in pilot and development projects. The advantage is the possibility of higher energy density and thus smaller volume. This can be an advantage if you have limited space or if the storage facility needs to be integrated close to consumption or production, where space is expensive or practically difficult.

An example from Norwegian research shows that salt hydrates can reduce storage size to around 25% of the volume compared to conventional hot water storage. In a Danish-Swiss development project involving salt hydrates, efficiency was improved from around 65% to 85% through the use of thin heat-conducting lamellas made from recycled aluminum, while charging and heat release were significantly accelerated. For you, this points to an important point: in latent thermal energy storage, heat transfer and geometry are often just as crucial as the material itself, because they affect how quickly the storage can be charged and discharged in practice.

Thermochemical thermal energy storage, where documentation is a prerequisite

Thermochemical storage is based on sorption or reversible chemical reactions and is described as experimental with limited performance data. This means that the basis for decision-making often requires clear acceptance criteria for documentation, testing, and operation before the technology can be evaluated against more mature solutions.

If you are considering thermochemical thermal energy storage, you should therefore be clear about what needs to be documented before the solution can be included in a commercial comparison. This may involve, for example, defined test scenarios, requirements for measurement points, and an operating plan that makes it possible to verify performance without compromising supply or process stability.

Thermal energy storage in practice: materials, energy density, and space requirements

The choice of thermal energy storage affects both energy density (energy per volume) and space requirements. The highest energy densities are found in thermochemical sorption storage, followed by hot water storage, latent organic PCM systems, and pit storage facilities. Lower energy densities are typically found in sensitive storage systems such as aquifer and borehole storage.

For you, this means that choosing a technology is not just a financial decision, but also a question of space, location, and integration. A storage facility with lower energy density may be entirely appropriate if you have the space and value robustness and simple operation above all else. Conversely, a more compact solution may make sense if layout, buildings, or safety zones make volume and location the real constraints.

It is also useful to distinguish between what the storage facility is intended to do: Is it primarily to even out daily variations, handle peak loads, or transfer energy between seasons? Clarifying this makes it easier to assess whether you need high power exchange or whether the total amount of stored energy is most important.

Thermal energy storage in district heating, where flexibility can be planned

Thermal energy storage plays a significant role in Denmark, where around 400 district heating companies operate, and many have invested in large underground storage facilities. A concrete example is an underground storage facility in Høje Taastrup with a capacity of 70,000m3 of hot water and a storage capacity of 3,300 MWh. The storage facility is connected to Copenhagen's main district heating pipeline and can store surplus heat from the pipeline for use when the price of other heating alternatives is high.

Traditionally, pit storage facilities are filled in the summer and emptied in the winter (one cycle). In Høje Taastrup, around 30 cycles are run annually, which shows that thermal energy storage can also be used for frequent flexibility – not just seasonal shifting.

For district heating, implementation often involves ensuring that the interaction between production, network, and storage works operationally: when to charge, when to discharge, and what restrictions apply in the distribution network. When storage becomes an active part of the operating plan (and not just seasonal storage), clear management principles and clear operating procedures become an important part of the value.

Thermal energy storage for cooling in data centers with RTES

A well-documented application of thermal energy storage is reservoir thermal energy storage (RTES) for data center cooling. Here, cold energy is stored underground and used during peak loads. In a modeled analysis with four wells drilled to a depth of 275 meters, performance was assessed over 20 years and compared with conventional cooling using dry coolers and vapor pressure compressor coolers.

RTES was less dependent on outdoor temperatures and showed almost seven times higher efficiency during summer peak loads: a coefficient of performance of 16.5 versus 2.4. At the same time, the levelized cost of cooling was reduced from $15/MWh to $5/MWh.

In practice, this example shows that thermal energy storage for cooling is particularly relevant when you have clear peak periods where conventional systems typically become less efficient or more expensive to run. Here, storage can act as a buffer that relieves the active cooling production, making operation more stable during peak loads. This does not change the requirements for operational monitoring and maintenance, but it can change when and how capacity is delivered.

The economics of thermal energy storage depend on operation and price dynamics

The economics of thermal energy storage depend mainly on the storage horizon, price dynamics (the difference between low and high prices), space availability, integration complexity, and operating and maintenance requirements. For heat production, the combination of heat pumps and thermal energy storage can reduce heating costs by up to 15% compared to heat pumps alone.

To assess whether the case is robust, you should consider whether the storage can be utilized often enough to have an effect and whether you have the necessary sales when the storage is discharged. It is also relevant to assess whether the storage reduces the need for peak loads or provides the freedom to run other facilities at more advantageous times. The more your operations can actually be shifted in time, the more likely it is that the storage can contribute positively to the overall economy.

Financing can also affect the business case. For district heating projects, including underground storage facilities, there are municipal credit funds with very low interest rates – even below 1% – for sustainable energy solutions. In this type of project, it is therefore practical to consider financing options early on, as this can affect both the scope and prioritization of the project.

Rules and frameworks for thermal energy storage in the EU and Denmark

Thermal energy storage is affected by both EU and Danish frameworks. The EU Energy Efficiency Directive (EU/2023/1791) makes "energy efficiency first" a fundamental principle and sets binding requirements for a further overall reduction in energy consumption by 2030. The directive also tightens the framework for heating and cooling, including the definition of efficient district heating and cooling, to support a decarbonized supply by 2050.

In practice, this means that documentation, planning, and prioritization of energy-efficient solutions will be given greater weight in decision-making processes. For you, it may be relevant to describe thermal energy storage as a specific operational measure: what the storage optimizes, what losses are acceptable, and how the solution supports a more efficient system across production and consumption.

Nationally, the Electricity Supply Act stipulates that electricity supply must be planned with regard to climate, environment, security of supply, consumer protection, and socio-economics—and it promotes, among other things, efficient energy use and flexibility in the energy system. In practice, this makes it relevant to consider thermal energy storage as a flexibility component that can take advantage of periods of lower electricity prices or high renewable production when it suits your operating framework.

Risks and pitfalls in thermal energy storage and how to reduce them

Thermal energy storage requires control of both technology and operation. There are also trade-offs between large amounts of energy (MWh) and high discharge power (kW) in practice. You should therefore treat risks as part of the design and operational basis, not as an afterthought.

Here are the typical risk points and how you can use them in your requirements specification and operating plan:

  • Heat loss: Must be addressed in design and operation, especially for longer storage periods. In practice, heat loss should be included in the dimensioning and in the expectation of how long energy can be stored without losing value.
  • Materials and pressure: Sensitive bearings require focus on corrosion, pressure conditions, and material selection that can withstand cyclic temperature changes. It is important that material selection, welds, and pressure design match actual operating cycles, not just a theoretical scenario.
  • Corrosion under insulation (SRC): Insulation can trap moisture against the tank surface, especially if the metal jacket or seal is compromised. Without regular inspection, critical signs can be overlooked, increasing the risk of leaks and downtime. It may therefore be relevant to plan inspection points and access conditions as early as the layout phase.
  • PCM requirements: Latent storage places higher demands on material stability and temperature range because the phase change must be achieved in order to be effective. In practice, this means that the operating strategy must be able to keep the storage within the relevant temperature window, otherwise the expected benefit will be reduced.
  • Technology risk: Thermochemical storage lacks efficiency data and typically requires pilot results and operational data before commercial comparison. Here, you should define what documentation is "good enough" before accepting scaling.

Overall, the best projects are typically those where risks are translated into specific requirements: what measurements are needed, what operating scenarios need to be handled, and what maintenance routines are required to maintain performance.

How to plan a thermal energy storage project step by step

A thermal energy storage project should be structured in such a way that you minimize risk and obtain a realistic basis for decision-making. This is particularly important in terms of obtaining the right clarifications before committing to technology and dimensions.

A simple and practical process might look like this:

  1. Needs assessment: Temperature requirements, operating scenarios, storage horizon, and existing infrastructure. Be sure to describe when the need arises (daily, weekly, seasonal) and whether power or energy volume is the primary constraint.
  2. System design and dimensioning: Focus on heat loss, materials, pressure design, and—importantly—the desired discharge effect during operation. Here, it is crucial to dimension for actual operating behavior so that the storage facility is not large but slow, or fast but too small in terms of energy volume.
  3. Integration: Dimensioning of heat exchangers and operating protocols so that charging takes place when electricity prices are low or renewable production is high. Integration is also about interfaces: who controls what, and which set points apply in normal operation and in the event of deviations.
  4. Testing and optimization: Many start with pilot installations to validate performance before full scaling and use operational data to adjust control. The purpose is to ensure that the expected flexibility can be delivered in practice and that the operations team has a simple basis for decision-making when charging or discharging.

At XOLTA, we take a solution-oriented approach to energy projects, where technical choices, integration, and operational reliability must be consistent in practice. For thermal energy storage, this means that you get a clear process for clarification, dimensioning, and risk management before you commit to a technology. This makes it easier to compare solutions on a uniform basis and to create an implementation that can be operated stably over time.

FAQs about thermal energy storage

  • What does thermal energy storage mean? It is the storage of heat or cold over time (from hours to seasons) so that the energy can be used when needed.
  • What types of thermal energy storage are there? The three main categories are sensible storage (most mature), latent storage with phase change materials (under development), and thermochemical storage (experimental).
  • Can thermal energy storage reduce costs? Yes, in relevant cases, thermal energy storage combined with heat pumps can reduce heating costs by up to 15% compared to heat pumps alone.
  • What is an example of large-scale thermal energy storage in Denmark? The underground storage facility in Høje Taastrup holds 70,000m3 of hot water and 3,300 MWh and operates at around 30 cycles per year.
  • How is thermal energy storage used in data centers? With RTES, cold is stored underground and used during peak loads; in a modeled analysis, cooling costs were reduced from $15 to $5/MWh, and efficiency during summer peaks was significantly higher than conventional cooling.
  • What are the main risks associated with thermal energy storage? Typical risks include heat loss, corrosion and pressure conditions in sensitive storage facilities, higher requirements for material stability and temperature range for PCM, and uncertainty and lack of efficiency data for thermochemical storage.

Contact us

Do you have questions or need advice? Our experts are ready to help you.

Contact support

If you would like to contact support, please call +45 35 153 123 or send an email to support@xolta.com.

Contact sales